Ghostbox
Do you sometimes feel like you're being watched by ghosts? Don't worry—our Ghostbox will give you the answer!
Combining state-of-the-art electronics with a charming retro design, the Ghostbox blends technology and mystery—perfect for your next ghost hunt.

Ghostbox
Degree Program
ET - Discontinued
Project Description
Do you sometimes feel like you’re being watched by ghosts? Don’t
despair—our Ghostbox will give you the answer!
Combining state-of-the-art electronics with a charming retro design, the Ghostbox blends technology and mystery—perfect for your next ghost hunt.
The goal of the “Ghostbox” project is to design and (further) develop a so-called REM pod, which measures changes in the electromagnetic field (EMF), temperature, as well as sounds and vibrations.
The goal is to explain unnatural deviations in the readings caused by the presence of possible ghosts and to protect the world from ghosts.
The Ghostbox’s portability allows users to explore places with a supernatural aura and investigate paranormal activity.
For detection, the device features 7 different operating modes from which the user can choose.
Should an encounter occur, the Ghostbox alerts the operator via visual and/or audible output, depending on the operating mode.
People Involved
Student group: Jonas Doll, Marco Gärtner, Marius Häderle, Niklas Schäfer
Advisor: Prof. Dr.-Ing. Wolfgang Meyer
Course
Systems Engineering 1 (IK)
Duration
Winter Semester 2024/25
Requirements
- Measurement of Changes in the Electromagnetic Field
- Measurement of temperature changes
- Measurement of vibrations/shocks
- Measurement of noise
- Continuous measurement
- Visual display of measured values; no mutual interference between sensors
- Sensor data is transmitted to a central logic unit
- On/Off switch
- Multiple operating modes
- Rechargeable power supply (lithium-polymer battery)
- Optimal performance under ideal conditions
- Fast and reliable response
- The device is portable
Implementation
For the EMF measurement, the idea arose to use the principle of a theremin (musical instrument). In this setup, the pitch changes as a hand approaches an antenna.
Through research, a suitable, ready-made circuit diagram for a theremin was found. An additional circuit was required to connect to the ESP32 via a custom-designed board.
For temperature, noise, and vibration measurements, off-the-shelf components were purchased and connected to the ESP32 via the custom board.
The visual output was implemented using a Neopixel ring with 16 LEDs, which can light up in different colors as needed.
To implement audio output, an audio amplifier board and a full-range speaker were purchased; the speaker outputs the theremin’s audio signals.
All inputs and outputs were connected to a custom-designed and assembled circuit board with a built-in ESP32. This board also controls the power supply, connects all buttons, sensors, LEDs, and other components, and includes all other auxiliary circuitry.
Software was installed on the ESP32 that processes all inputs and outputs collectively.
The enclosure is an antique wooden box that was modified for the purposes of the project. The mount for the ghost, the antenna, the knobs, and the control panel were designed in CAD software, 3D-printed, and screwed into place. The ghost was also 3D-printed, though using a template found online.
Uses
The Ghostbox is used for ghost hunting. The user can choose whether to set it up in one place to detect changes or to proactively explore while holding the Ghostbox in hand.
In both cases, after setting the mode, the ghost hunter is alerted to the presence of a ghost either by a visual signal, an audible signal, or a combination of both. To do this, the user simply needs to position the Ghostbox correctly with the spirit facing away from them and, if necessary, extend the antenna and adjust the sensitivity using the tuning control. Thanks to the lithium-polymer battery, the hunter has about 3 to 4 hours per charge for ghost hunting.
However, the Ghostbox must not be used in rain, thunderstorms, or generally wet conditions, and should only be used within a temperature range of 0°C to 40°C.











